Home > News > Importance of structural design of multi-storey prefabricated workshop building
CONTACT US
  • Address:Pingtang Industrial District, Shipeng Village, Shishan Town, Nanhai District, Foshan City,
  • Phone:0757-81002668/0757-63323396
  • Fax:0757-81196682
  • Contact:Ben Zheng/13826981293 Kerry Lu/13751224830
  • E-mail:sbs@sbsprefabhouse.com
  • URL:http://www.ggscp.cn

Importance of structural design of multi-storey prefabricated workshop building

Time:[2022-4-29]  Hits:2704

In recent years, with the development of the diversity of the world economy, the industrial production of various countries and regions has also been continuously improved, and the complexity of the process layout is a revolutionary change for the industrial workshop buildings with single production function and simple building layout in the past; At the same time, the popularization of computers and the integration and simplification of structural calculation software have solved the complex and cumbersome structural calculation problems. As a result, multi-storey and even high-rise productive industrial buildings with large span, large space and complex building layout have emerged. Under the background of such rapid development, the rational selection of building structure layout and design parameters has played an important role in structural design.

1. Characteristics of multi-storey prefabricated workshop building

1.1 plane structure layout and column grid layout

In the plane layout of multi-storey prefabricated workshop building, usually in order to meet the process requirements: the structural layout is irregular, the pole network is irregular, and the beam layout is irregular, so there is the phenomenon of opening holes on the main stressed components according to the process requirements. At the same time, the internal space of the workshop building is generally large, and the column spacing is mostly 6 ~ 12m; The same part has the design of pulling column; The column spacing will increase to more than 18m. This makes the force transmission of the structure complex, the force is not clear, and the phenomenon of stress concentration is easy to occur in the design.

1.2 vertical structure layout and floor height

The storey height of multi-storey prefabricated workshop building is large, which can reach 4 ~ 8m, and there are often staggered floors and interlayer in the vertical layout, and large holes are opened in the floor, which makes the floor unable to provide sufficient in-plane stiffness, and the effective mass of the structure is unevenly distributed along the vertical direction. Under the action of earthquake, the structure may produce "short column effect", which makes the horizontal shear force of local column section become the control factor of section design.

1.3 various types of loads

The concentrated load of industrial workshop building mainly includes the self weight of equipment, and sometimes the vibration disturbance of equipment needs to be considered, and the dynamic calculation is carried out according to the requirements of the specification. Suspension load mainly includes pipeline load and crane load, and sometimes the pipeline also produces horizontal load and bending moment. The plate surface load is mainly based on the requirements of production technology. There are different values of live load on the ground of different production buildings, but this kind of live load is generally greater than that in civil buildings.


1.4 floor and foundation form

The cast-in-situ reinforced concrete floor is generally adopted for the floor of industrial workshop building. However, due to the equipment load requirements proposed by the process, the floor may have holes or local thickness changes. The foundation form of the powerhouse mostly adopts the independent foundation under the column and the strip foundation under the column. If the bearing capacity of the foundation is low, the lime soil compaction pile, sand pile and other methods can be used to deal with it, or the cast-in-place pile can be used to act directly on the hard soil layer.

1.5 light envelope

Generally, the enclosure structure of industrial workshop building is not used as a load-bearing system, and light materials are usually used. The roof structure mostly adopts steel truss purlin system with light insulation layer. This light enclosure material is beneficial to reduce the self weight of the structure and reduce the seismic response.

Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號
主站蜘蛛池模板: 成年女人毛片免费视频 | 久久99精品久久久久久野外 | 嫩草成人影院 | 亚洲精品欧美日本中文字幕 | 亚洲欧洲自拍 | 91看片淫黄大片在看 | 日本特黄视频 | 久草视频这里只有精品 | 国产成人精品曰本亚洲 | jizz亚洲人| 婷婷五月在线视频 | 国产人成在线视频 | 亚洲色图男人天堂 | 国内自拍视频在线播放 | 日韩欧美一区二区三区中文精品 | 美国农夫激情在线综合 | 好爽好深好猛好舒服视频上 | 亚洲无吗在线视频 | 日本中文不卡 | 最近最新2019年中文字幕 | 日日摸夜夜摸无需播放器 | 国产成人永久在线播放 | 日本一区二区三区中文字幕视频 | 9久9久女女热精品视频免费观看 | 国产伊人网 | 韩国专线1区| 97国产成人精品视频 | 花季v3.351 | 久热这里有精品 | 亚洲se网 | 99精品视频在线免费观看 | 欧美成人精品第一区二区三区 | 黄视频网站免费 | 亚洲天天综合 | 国产免费播放一区二区 | 91免费精品国偷自产在线在线 | 青青青免费手机版视频在线观看 | 亚洲男人影院 | 青青青青青国产免费手机看视频 | 欧美在线观看网站 | 草莓视频免费下载观看丝瓜 |